New Submissions Are Not Currently Being Accepted
Samples sent after April 10, 2024 will be put on hold.
Viewing desktop version: Switch to Mobile
Brown Powder (Psilicyben)
Sold as: Psilocybin
ID: 7826
Test Date: Oct 03, 2019
Pub. Date: Oct 03, 2019
Src Location: Troy, MI
Submitter Loc: Troy, MI
United States
Color: Brown / Green
Size: 600 mg, 23.30 mm x 8.10 mm
Data Source: DrugsData
Tested by: DDL
Lab's ID: 20190900080
Sample contains multiple unidentified chemicals.
Sold as: Psilocybin
Expected to be: MDMA
Lab comments:
Analyzed multiple times. No psilocybin detected.
Two capsules of green-brown powder.
See images of spectra, left, that correspond to the four unidentified compounds detected in this sample, referred to as Unidentified 1, 2, 3 and 4. Unidentified 1 (8), Linoleic acid (6), Unidentified 2 (2), Unidentified 3 (1), Unidentified 4 (6).

The main reason to use DrugsData to test an herbal product is if a specific chemical (like psilocybin or psilocin) is expected to be in the sample, or if it is suspected of being adulterated. Other minor components of plant material may or may not be detectable or identified by current GC/MS methods utilized by the lab we work with.
Unidentifed Substances
This sample contains an unidentified chemical. We do not have a matching substance in our lab's internal database and have not yet been able to identify the chemical(s).

We need the help of outside expert analytical chemists and drug geeks to determine what substance matches the mass spectrum (MS) fingerprint. The lab's GC/MS graphs can be viewed by clicking on the thumbnails on this page.

Please use our contact form and include the DrugsData ID (7826) or this URL along with any communications.