ID: | 2430 |
---|---|
Name: | Shell |
Other Names: | |
Marquis:The Marquis Test is a reagent field test conducted by placing a drop of reagent liquid onto a small sample of the material being tested. The chemicals in the reagent react differently with different chemicals, turning a variety of colors based on the what is in the material being tested. | No Reaction (The lab's reagents might be old and non-reactive, so we would not trust this 'no reaction' finding.) |
Mecke:As with the Marquis Test, The Mecke Test is a reagent field test conducted by placing a drop of liquid reagent onto a sample of the material in question. Mecke reagent is primarily used for the identification of heroin and other opiates. | No Reaction |
GC/MS:The GC/MS Lab Test | |
Test Date: | Feb 27, 2012 |
---|---|
Pub. Date: | Feb 27, 2012 |
Src Location: | Madison, WI |
Submitter Loc: | Madison, WI United States |
Color: | Yellow |
Size: | 284 mg, 9.40 mm x 11.50 mm |
Data Source: | DrugsData (EcstasyData) |
Tested by: | DDL |
Lab's ID: | 20120200017 |
We need the help of outside expert analytical chemists and drug geeks to determine what substance matches the mass spectrum (MS) fingerprint. The lab's GC/MS graphs can be viewed by clicking on the thumbnails on this page.
Please use our contact form and include the DrugsData ID (2430) or this URL along with any communications.